Materials Growth

ICP-CVD cluster, 2 sets | Located at 118, Physics Building
The ICP-CVD system contains two chambers, one is main chamber with hot plate (4 inch, up to 1000 C), plasma power(<1000 W), controllable pressure (1 to 100 mTorr), and four mass flow meters, the other chamber is for loadlocking or transfer to glovebox. The system can be operated on computer for all procedure. It can be used for the growth of different kinds of two dimensional materials, especially graphene and h-BN.

Sputter system, 1 set | Located at 110, Physics Building
The sputter system contains two chambers, one is main chamber with hot plate (4 inch, up to 500 C), plasma power(<500 W), controllable pressure (1 to 100 mTorr), and two mass flow meters, the other chamber is for loadlocking. It can be used for the coating different metal films, especially single crystalline Cu, Ni films.


ICP-CVD cluster, 2 sets | Located at 118, Physics Building
The ICP-CVD system contains two chambers, one is main chamber with hot plate (4 inch, up to 1000 C), plasma power(<1000 W), controllable pressure (1 to 100 mTorr), and four mass flow meters, the other chamber is for loadlocking or transfer to glovebox. The system can be operated on computer for all procedure. It can be used for the growth of different kinds of two dimensional materials, especially graphene and h-BN.

Sputter system, 1 set | Located at 110, Physics Building
The sputter system contains two chambers, one is main chamber with hot plate (4 inch, up to 500 C), plasma power(<500 W), controllable pressure (1 to 100 mTorr), and two mass flow meters, the other chamber is for loadlocking. It can be used for the coating different metal films, especially single crystalline Cu, Ni films.
Low Pressure Chemical Vapor Deposition System (LP-CVD) | Located at 237, Physics Building
There are three similar LP-CVD systems installed here, they contain one tube furnce (1 inch, up to 1200 C, MIT from KJMT), four mass flow meters (Sevenstar), one vacuum pump, and one full range gauge. It can be used for the growth of different kinds of two dimensional materials.

Plasma Enhanced Chemical Vapor Deposition System (PE-CVD) | Located at 237, Physics Building
The PE-CVD system contains one tube furnce (1 inch, up to 1200 C, MIT from KJMT), four mass flow meters (Sevenstar), one vacuum pump, one full range gauge, and one plasma source (300W, K-mate). It can be used for the growth of different kinds of two dimensional materials, especially graphene.
Characterization

FastScan Atomic Force Microscope (AFM) | Located at 235, Physics Building
Bruker Dimension FastScan, it contains different measurement mode, including Peak Force Tapping, Contact Mode, Tapping Mode, Phase Imaging, Life Mode, EFM, MFM, KFM, ScanAsyst, LFM, Force Curve. In Tapping Mode, it can reach the fastest scanning rate (>10 Hz) with the same accracy.

Raman/PL system | Located at 235, Physics Building
WITec alpha 300R with 532 nm laser. It contains Raman (1 or 3 cm-1 energy resolusion) and PL, 2D and 3D mapping.

Optical Mcroscope (OM) | Located at 235, Physics Building
Nikon LV100ND, it contains different obsearvation modes, including bright field, dark field, fluorescence image, polarization image, etc..
Transport Measurement

Agilent B1500A semiconductor device analyzer | Located at 235, Physics Building
Agilent B1500A semiconductor device analyzer of integrated a variety of measurements and analysis functions into one instrument, which can characterize the device quickly and accurately. It is the only multi-function parameter analysis instrument which is able to provide a wide range of device characterization function and the best measurement reliability and repeatability. It is capable of performing a full range measurement from the basis of the current voltage (IV) and capacitance voltage (CV) characterization to the optimum fast pulse IV test.

Oxford Instrument Cryogen-free Superconducting Magnet System | Located at 235, Physics Building
Oxford Instrument cryogen-free superconducting magnet system providing top loading access to a sample in a variable magnetic field / low temperature environment. Standard magnetic fields up to 9 T in a compact geometry. No cryogens needed just electricity supply. With a Variable Temperature Insert, the lowest temperature can reach 1.5 K. Based on this cryogen-free superconducting magnet system, we can proceed transport measurement at low temperature and high magnet field.
http://cvd.nju.edu.cn/ywzxx/yqsb/index.html